Replace Blower Motor
Heater with motor that needed to be replaced.

Here are the tech notes.

GEN3 was called to your home today to take a look at your ac system that stopped cooling. Upon inspection, we found the indoor coil completely frozen. We found the indoor fan motor extremely hot to the touch and burnt smell. We then jumped out the fan and got no operation. This indicates that the fan motor has burned out. We will need to replace the motor and capacitor to further evaluate for any other issues within up the ac system. The motor is 3-day lead and will require a 30% deposit. Thank you for choosing GEN3!

Step 1: Remove the fan assembely

Old Blower motor in the fan assembly removed.
Removing the Fan assembly from the furnace cabinet is the first step to replacing the blower motor. Once removed, you’ll notice that the blower motor is located in the center and is attached to three nuts. It’s also held by a motor harness, adding to the durability and longevity of the furnace. Upon closer inspection, it’s not uncommon to see heat damage and dirt buildup that needs to be addressed. Replacing the blower motor not only restores your furnace to optimal condition but also ensures that your home stays warm and cozy during the colder months. So don’t hesitate to take action and give your furnace the care it deserves!

Step 2: Clean the housing

Fan assembly with the blower motor removed.
Replacing a blower motor is a task that requires attention to detail. Once you’ve identified the blower motor and removed it, what’s left behind is the fan assembly. The center shaft is crucial since the new motor must fit onto this shaft. In addition, it’s important to clean the entire system before installing the new motor. Over time, air can accumulate dirt, and this can lead to equipment damage, eventually burning out the motor. To avoid such issues, it’s necessary to have a service or maintenance plan. By doing so, you can ensure that your equipment runs smoothly and efficiently.

Step 3: Install the new motor.

New motor installed in the fan assemble.
Congratulations, you’ve made it to the final step in replacing the blower motor! With the fan assemble and cleaned, the new motor is ready to be attached to the fan shaft and the fan harness can be reattached. Don’t forget to properly balance the motor by attaching it to the three bolts. Now, all that’s left to do is install the fan assembly back into the furnace cabinet and wire the fan into the control board. Voila! Your system will be as good as new and ready to provide warmth or coolness with a brand new blower motor.

Share:

Facebook
Twitter
LinkedIn
More Posts

How Old Is Your Electrical Panel? 

From old fuse boxes to today’s smart load centers, your electrical panel tells the story of your home’s evolution. Many older panels, like Pushmatic, Federal Pacific, and Zinsco — can pose safety risks or struggle to keep up with modern electrical demands. Learn how to identify your panel’s age, the signs it’s time for an upgrade, and how modern smart panels are changing the way Philadelphia homeowners manage energy, safety, and efficiency.

5 Signs Your Furnace Needs Maintenance Before Winter Hits

As Philly temperatures drop, your furnace becomes the heart of your home’s comfort, but even the hardest-working system needs care to perform its best. Regular furnace maintenance keeps your home safe, efficient, and ready for winter. Learn the top 5 signs your furnace needs attention and why scheduling a $59 tune-up with GEN3 Electric & HVAC before the cold hits is the smartest way to stay warm all season long.

Mitsubishi Ductless Mini-Split Installation in Philadelphia 

GEN3 Electric & HVAC technicians Eric, Cush, and Luis recently completed a three-zone Mitsubishi ductless mini-split installation in Roxborough, Philadelphia. The team designed a clean, energy-efficient setup that delivers year-round comfort using Mitsubishi’s Hyper-Heating technology. Each indoor unit was strategically placed for airflow and comfort, while the outdoor condenser was mounted on wall brackets for protection and performance. From insulated line sets to professional PVC finishes, every detail reflects GEN3’s craftsmanship and care. Homeowners in Philadelphia’s historic neighborhoods can enjoy modern comfort without major renovations, thanks to reliable ductless solutions installed the GEN3 way.

Collage of GEN3 Electric & HVAC technicians installing a rooftop AC system in Philadelphia, including crane lift, condenser setup, and refrigerant line work, with city skyline in the background.

Philadelphia HVAC Replacement: From Old to New  

GEN3 Electric & HVAC transformed a rusted rooftop AC into reliable comfort for a condo in Philadelphia. From crane lifts to high-efficiency upgrades, discover how our expert team delivered energy savings, modern performance, and 5-star service.

Request Service Today!